Rotor Flowmeter
Features
◉ Excellent low-flow performance

◉ Versatile design may be used for gas, steam, and liquids     

◉ Low pressure loss for gas and steam applications                

◉ Suitable for high pressure and high temperature applications  

◉ Turn-down ratio of 10:1
◉ Local indication and intelligent remote LCD display  

◉ Easy-to-read analog pointer style indicator

◉ Intrinsically safe & explosion proof for hazardous area applications


Request a quote

PRODUCT DETAILS

Introduction
Specifications
Documents
Applications

F8001 rugged metal tube variable area meters (rotameters) are ideal for high pressure, high temperature and other demanding flow applications where safety is a concern. Features include: globally-recognized approvals for use in hazardous environments; analog and digital LCD local display options, multiple process connection options; several avaliable materials of construction for metering of aggressive fluids and corrosion resistance; HART enabled 4-20mA output to provide for remote monitoring and control. The F8001's excellent repeatability makes it a good choice for batching applications. For versions without electronic output, no power supply is required. The F8001's low-pressure drop provides additional value by allowing for economical pump selection.

 Size                15 ~ 150mm                
 Measuring Range                Water (20℃) 15 ~ 150,000 l/h                
Air (20℃, 0.1013MPa) 0.7 ~ 1000 m3/h                
 Temperature                Standard (E) -40 ~ +200℃, PTFE: -40 ~ 80℃                
High temperature (H): +200 ~ +400℃ 6.5 ~ 15.6 KPa                
 Pressure Loss  Pressure                Standard: 1.6MPa (DN65 - DN150) 4.0MPa (DN15 - DN50)                
High: 2.5MPa (DN65 - DN100) 6.4MPa (DN15 - DN50)                
 Viscosity                15m ~ 20 mm - < 30 CP                
25mm ~ 40 mm - < 250 CP                
50mm ~ 200mm - < 300 CP                
Top enter、Top exit                
 Wetted parts                SS #304 standard, SS #316 optional Tantalum (flow tube) PTEE (flow tube)                
PTFE lining                
ANSI and DIN-type avaialble                
 Flanges   Accuracy                ±1.5%(Standard)                
±2.5%(PTFE liner)                
 Repeatability                ±0.5% of reading                
Signal Output                4-20mA (2-wire)                
Local Display                Mechanical Indicator (standard)                
Digital Display                Rate 0 ~ 50000                
Total                0 ~ 99999999 (with decimal)                
 Power Supply                Standard:24VDC,two                
wire4~20mA(18VDC~30VDC)                
3.6VDC @ 5.2 AmpHours Lithium                
Approvals                Isolation: Exd Ⅱ CT5 Intrinsic Safety: ExiaⅡC                
Alarms                High / Low limit alarm maximum 1A @ 24VDC                
 Data Storage                EEPROM (up to 10 years)                
 Flow Orientation                Top enter/top exit, Standard                
Bottom enter/Top exit                 
Right enter/Left exit                
 Left enter/Right exit                
 Protection                IP 67                
 Housing Material                Aluminum                
 Cable Connector                M20x1.5 or ½" NPT                

Rotor Flowmeter

Rotor Flowmeter

Rotor Flowmeter

Rotor Flowmeter

Rotor Flowmeter